Add to Cart
Z-Zone BFS Plastic Ampoule Leak Testing Machine
Applications
The machine is dedicated to detect the conjoined plastic ampoule for possible liquid leak in all directions. As well as conjoined eyedrops, conjoined oral liquid etc. are available.
Parameters
Application | Height of conjoined plastic ampoule 65≤H≤120mm |
Length of conjoined plastic ampoule | L≤220mm(customization is available) |
Output | 0-80 Row/min |
Electric capacity | 3kW, 380V 50Hz |
Detecting Channel Power | 200W |
Voltage of High frequency high voltage | 0~30kV adjustable |
Frequency of High frequency high voltage | 0~10kHz adjustable |
Dimension | 2800mm X935mmX1650mm |
Weight | about 1200kg |
Work principle
Put the conjoined plastic ampoule to the interval of transporter, which would transfer the ampoule to detecting channel. There have two detecting channels(channel 1 and channel 2) which respectively detect the head ,body and bottom of ampoule; Then the ampoule reach to turn-over mechanism and be transferred to channel 3 and channel 4,which would detect the head, body and bottom on the other side of ampoule; Finally the reject unit would separate the qualified and unqualified; The qualified would be transfered to next station by conveyer bell mesh, and the unqualified would be transferred to unqualified collection device(As it would be prepared by clients, it isn’t showed on the graph as below)